89
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
this post was submitted on 21 Dec 2024
89 points (100.0% liked)
World News
22096 readers
221 users here now
Breaking news from around the world.
News that is American but has an international facet may also be posted here.
Guidelines for submissions:
- Where possible, post the original source of information.
- If there is a paywall, you can use alternative sources or provide an archive.today, 12ft.io, etc. link in the body.
- Do not editorialize titles. Preserve the original title when possible; edits for clarity are fine.
- Do not post ragebait or shock stories. These will be removed.
- Do not post tabloid or blogspam stories. These will be removed.
- Social media should be a source of last resort.
These guidelines will be enforced on a know-it-when-I-see-it basis.
For US News, see the US News community.
This community's icon was made by Aaron Schneider, under the CC-BY-NC-SA 4.0 license.
founded 2 years ago
MODERATORS
Why the fuck is that a fear?!?
Because back feeding the grid means the power company can’t shut the power down to work on a line. It requires coordinating everyone that might have something like this to unplug it. Rooftop installations add controllers to only supply when grid power is on, or to disconnect the house from the grid. Same thing when you add a generator inlet you’re supposed to also add a grid disconnect.
You're sure these kits in Germany dont have that check in place? If I know Germans, it does.
I live in Germany, and I can assure you no such check exists. I have one of these systems (although I don't plug mine into the grid, I store power in batteries and use it)
I'm not sure how the electricians protect themselves, I can only assume that they measure for voltage on the line after disconnecting from the grid, and then search for the culprits. Generally speaking any service providers inform residents well beforehand about outages, and there might be fines if you hold back work? I haven't looked into it, perhaps someone else has more info.
The system can only feed into your house line if there is an external 230V 50Hz power net working. The moment the net goes down there will be no power from your micro inverter to your house. It requires power to work and a stable 50 Hz similar to most bigger inverters.
If you combine a power station (battery) with the inverter, this battery might give you a 230V outlet with stable 50 Hz. But this is not the one you should plug back into your house (would require an unsafe cable).
Overall, lots of fear and wrong information in this thread about safety. There is a DIN norm for all of this and the current 800W limit exists to keep your power line from melting in the walls in the most extreme cases.
it’s for the safety of people working on the grid. solar panels in general have either to be isolated from the grid or disconnect if the grid is down. they are not allowed to spill into the grid if the grid has no power.
I dont understand. These people can just install more switches to solve this problem, right?
We were just dumb before and thought power was unidirectional. Now we have evolved into a decentralized grid. So we just need to add another switch to cut off power coming out of every room, building, etc. Right?
That seems like the obvious long-term, safest solution.
We have regulations here in Germany (EU wide even if I am not mistaken). The solar inverters used are required to shut off within I think 200ms of the 50hz grid power going down. The inverters sold here can't output anything without grid power being detected on the AC output.
Why is everyone in this thread making assumptions and spreading fear instead of actually looking up how it works?
And in addition to them backfeeding into the grid , they bypass all the fuses and GFCI protections your house might have and effectively require the use of a suicide cord. That part of a plug should never be providing power, only using it.